Part 21 Report - 1997-560

LICENSEE: ABB COMBUSTION ENGINEERING SITE: ABB COMBUSTION ENGINEERING EN NUMBER:32762 DOCKET: EVENT DATE: 08-14-97 RX TYPE: EVENT TIME: 00:00 VENDORS: NOTIFY DATE: 08-14-97 EMERGENCY CLASS: N/A REGION: 1 STATE: CT TIME: 14:24 OPS OFFICER: BOB STRANSKY 10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH 10 CFR PART 21 REPORT ENERGY REDISTRIBUTION FACTORS USED IN LARGE-BREAK LOSS OF COOLANT ACCIDENT ANALYSES DO NOT DIRECTLY REFLECT THE EFFECTS OF MODERATOR VOIDING. SPECIFICALLY, THE ENERGY REDISTRIBUTION FACTORS ARE UNDER PREDICTED BY 0.5% TO 1.5%. THIS CORRESPONDS TO A 20�F TO 60�F INCREASE IN PEAK CLAD TEMPERATURE DURING LARGE-BREAK LOSS OF COOLANT ACCIDENTS. THE FOLLOWING UNITS ARE AFFECTED: PALO VERDE UNITS 1, 2, AND 3; SAN ONOFRE UNITS 2 AND 3; WATERFORD UNIT 3; ARKANSAS NUCLEAR ONE UNIT 2; CALVERT CLIFFS UNITS 1 AND 2; AND SAINT LUCIE UNIT 2.

Page Last Reviewed/Updated Tuesday, March 09, 2021