Part 21 Report - 1998-220
ACCESSION #: 9802240259
Illinois Power Company
Clinton Power Station
P.O. Box 678
Clinton, IL 61727
Tel 217 935-5623
Fax 217 935-4632
Walter G. MacFarland IV
Chief Nuclear Officer
ILLINOIS
POWER U-602939
An Illinova Company 4F.140
February 17, 1998
Docket No. 50-461 10CFR21.21
Document Control Desk
Nuclear Regulatory Commission
Washington, D.C. 20555
Subject: 10CFR21 Interim Report 21-97-060: Sentry Equipment Corporation
Commercial Grade Dedication Program Deficiencies
Dear Madam or Sir:
On December 18, 1997, Illinois Power (P) found that Sentry Equipment
Corporation (Sentry) did not have documented procedures describing their
commercial grade dedication process. As a result, Sentry lacked
sufficient objective evidence to provide reasonable assurance that items
supplied to Illinois Power by Sentry have been procured or tested to
requirements needed to demonstrate the capability of the parts to perform
their intended safety function. This deficiency was identified during a
triennial supplier audit performed to verify adequacy and implementation
of the Sentry written quality assurance program. Sentry supplies IP with
replacement parts for the two Drywell and Containment Hydrogen and Oxygen
Analyzers at the Clinton Power Station.
IP determined this issue was potentially reportable under the
provisions of 10CFR21 on December 23, 1997.
Condition Report 1-97-12-289 was initiated to track investigation
and resolution of this issue. IP's evaluation of this issue under the
provisions of 10CFR21 has not been completed. The evaluation of this
issue will be completed by April 4, 1998.
U-602939
Page 2
Additional information about this issue may be obtained by
contacting R. D. Weber, Supervisor-Procurement Engineering, at (217) 935-
8881, extension 3785.
Sincerely yours,
Walter G. MacFarland, IV
Chief Nuclear Officer
RSF/krk
cc: NRC Clinton Licensing Project Manager
NRC Resident Office, V-690
Regional Administrator, Region III, USNRC
G. C. Wright, Region III, USNRC
Illinois Department of Nuclear Safety
INPO Records Center
Sentry Equipment Corporation
*** END OF DOCUMENT ***