Part 21 Report - 2002-300
ENGINE SYSTEMS, INC.
1220 S. Washington St, Rocky Mount, NC 27801 Telephone: 2521977-2720
P.O: Box 1928, Rocky Mount, NC 27802-1928 Fax: 2521446-1134
October 4, 2002
U.S. Nuclear Regulator Commission
Document Control Desk
Mail Stop 0P1-17
Washington, DC 20555
Subject: 1OCFR21 Reporting of Defects and Non-Compliance -
Engine Systems, Inc. Report No. 1OCFR21-0085, Rev.0
EMD Engine-Driven Water Pump Assemblies
Dear Sir:
The enclosed report addresses a reportable notification about EMD engine-driven water pump assemblies.
A copy of the report has also been sent to the NRC.
Please sign below, acknowledging receipt of this report, and return a copy to the attention of Document Control at the address above (or, fax to number 252/446-1134) within 10 working days after receipt.
Yours very truly,
ENGINE SYSTEMS, INC.
Susan Woolard
Document Control
Please let us know if ANY of your mailing information changes - name of recipient, name of companylfacility, address, etc. Mark the changes on this acknowledgment form and send to us by mail or FAX to the number above.
RECEIVED: ___________________
(93)
DATE: __________________
Quality Performance With Pride
ENGINE SYSTEMS, INC.
1220 S. Washington St, Rocky Mount, NC 27801 Telephone: 2521977-2720
P.O: Box 1928, Rocky Mount, NC 27802-1928 Fax: 2521446-1134
Report No. 1OCFR21-OO85
Rev.0: October 04, 2002
IOCFR2I REPORTING OF DEFECTS
AND NON-COMPLIANCE
COMPONENT:
Engine Water Pumps
EMD PIN 40089540, 40089541, 40089881, 40089882
SYSTEM:
EMD Emergency Diesel Generators
CONCLUSION:
Reportable in accordance with 1OCFR21.
Prepared By: Date:________
Engineering Manager
Approved By:___________________________ Date:________
Quality Assurance Manager
ORIGINAL
When Stamped In Blue
Quality Performance With Pride
Report No.1OCFR21-0085
Record of Revisions
PAGE: l of 1
REV DATE PAGE DESCRIPTION
Report No. 1OCFR21-0085
Revision: 0
Date: 10104102
Page: 1 of 4
COMPONENT:
Engine Driven Water Pumps, EMD P/N 40089540, 40089541, 40089881, 40089882.
SUMMARY:
Engine Systems Inc. (ESI) has concluded its investigation of a condition reported with EMD engine-driven water pump assemblies. The condition identifies an occurrence wherein, following installation, a seal within the pump assembly prematurely fails resulting in the leakage of cooling water or lubricating oil from the weep hole on the water pump housing.
The issue was discovered by EMD as a result of field experience in the locomotive and marine applications.
DISCUSSION:
A cross-sectional view of the EMD standard water pump is shown in Figure 1 of this report.
The water pump impeller and shaft assembly is supported in the housing by two roller bearing assemblies, item 11. The bearings are lubricated by splashed engine lube oil entering through the inlet hole, item 3, located in the top of the drive end of the support housing. Oil exits the bearing cavity through the oil outlet hole, item 12, located in the bottom of the drive end of the support housing. The cooling water is sealed through a mechanical seal assembly located at the impeller end of the shaft assembly, items 15, 17, 18 & 19. The cavity between the bearings and mechanical seal contains a drilled passage (weep hole) to provide an external visual indication of leakage of water from the mechanical seal as well as to prevent water from contaminating the bearings and engine oil system.
In an effort to extend the service life of the water pump assemblies, EMD redesigned the bearings, shaft and support housing to utilize tapered roller bearings in lieu of spherical roller bearings. The tapered roller bearings were mounted as opposed pairs in a back-to-back arrangement. A seal was installed at the opposite-drive end of the shaft to prevent oil leakage into the cavity and out the weep hole. This modification was incorporated on all water pumps applicable to 16 & 20 cylinder EMD engines. The earlier design pumps utilizing spherical bearings were discontinued in April, 2000.
Through the locomotive and marine industry, EMD has found that the redesigned pumps are experiencing premature failures of the internal seals resulting in leakage via the weep hole. The primary leaking fluid is engine cooling water, however, leakage of lubricating oil from the bearing side is a possibility. The seals are failing as a result of an insufficient preload on the tapered roller bearings. Without adequate preload, there exists excessive clearance between the rollers and race. This clearance results in chattering of the rolling elements and relative movement of the shaft within the pump. The issue applies to the design of the pump assembly relating to establishing and maintaining adequate preload on the bearings during operation. The problem is not a result of incorrect assembly.
No failures have been reported of the bearings, drive gear or loss of function of the pump assembly.
Report No. 10CFR21-0085
Revision: 0
Date: 10/04/02
Page: 2 of 4
1 Waler Slingere Water Pump Shalt 15 Carbon Seal
2 Support Housing 9 Drive Gear Kev l6 Impeller Housing
3 Oil Inlet 10 Drive Gear 17 Staticnarv Bushing
4 Bearing Retainer Ring 11 Bearing AsSembly 18 Outer Seal
5 Snap Ring 12 Oil Outlet 19 Seal Retainer Spring
6 Gear Retainer Washer 13 Roll Pin And Spring 20 Impeller
7 Gear Retaining Nut 14 Bearing Spacer 21 Impeller Retainer Key
FIGURE 1
Water Pump Cross Section
Report No. 1OCFR21-0085
Revision: 0
Date: 10104102
Page: 3 of4
CONCLUSION:
Failure of the seals within the water pump as a result of this condition primarily results in a loss of engine coolant through the weep hole. Because nuclear applications often require extended operation with a minimal amount of maintenance while operating, this leakage, if left unattended, could compromise function of the emergency diesel generator set.
CUSTOMERS AFFECTED:
ESI has searched its historical data and has determined the following customers have purchased the water pump assemblies utilizing tapered roller bearings for safety-related applications:
CUSTOMER SITE
Dominion Virginia Power Corp. Surry Nuclear Power Plant Entergy Operations Arkansas One Nuclear Power Plant Florida Power & Light Co. St. Lucie Nuclear Power Plant Florida Power & Light Co. Turkey Point Nuclear Power Plant Korea Hydro & Nuclear Power Co. Kori II Nuclear Power Plant Pooled Equipment Inventory Co. N/A Westinghouse Savannah River Co. Savannah River Nuclear Plant Wisconsin Public Service Corp. Kewaunee Nuclear Power Plant
Report No. 10CFR21-0085
Revision: 0
Date: 10/04102
Page: 4 of 4
CORRECTIVE ACTION:
No method is available to indicate the condition of the seals within the water pump assembly. The service history of the pumps with tapered bearings has indicated the seal failures occur either immediately or prematurely after a low number of operating hours. It is for this reason that it is recommended to replace the tapered bearing pumps with the previous design units using standard roller bearings.
Perform an inspection of the weep hole of each water pump to determine if leakage is present.
Note:
It is not uncommon for the EMD water pump to leak a small amount of water from the weep hole when initially installed. After a small amount of run time, however, the sealing surfaces of the mechanical seal will mate and the leak should di~appear.
Replace the tapered roller bearing water pump assemblies with standard roller bearing water pumps as identified below. Use the leakage rate (if present) as an indicator of the urgency of pump replacement. If no leakage is present, continue with monthly leak inspections and replace the pumps at the next available opportunity.
Tapered Beanng Standard Roller
Pump PIN Bearing Pump PIN Application
40089540 4000423416 & 20 Cylinder 645 engines, LIB,
Left Hand Rotation
40089541 4000423516 & 20 Cylinder 645 engines, RIB,
Left Hand Rotation
40089881 836423716 & 20 Cylinder 645 engines, LIB,
__________________ Right Hand Rotation
40089882 836423616 & 20 Cylinder 645 engines, RIB,
__________________ Right Hand Rotation
Attachment