Result of BETHSY Test 9.1.b Using RELAP5/MOD3 (NUREG/IA-0141)
On this page:
Download complete document
Publication Information
Date Published: August 1998
Prepared by:
S. Petelin, B. Mavko, O. Gortnar, I. Ravnikar, G. Cerne
University of Ljubljana
"Jožef Stefan" Institute
Ljubljana, Slovenia
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment and Maintenance Program
(CAMP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Availability Notice
Abstract
RELAP5 computer code was used to simulate an experiment designated 9.1.b, (2" Cold Leg Break without HPSI and with Delayed Ultimate Procedure) performed on BETHSY integral test facility. This test is characterized as beyond design transients scenarios with unavailability of some safety and protection systems. The calculations which have been completed using the computer Sun Sparcstation 20 aim to evidence the difference between experimental and computed data. Generally, an agreement of major transient treads is shown to be obtained in the simulation.
Page Last Reviewed/Updated Tuesday, March 09, 2021