Part 21 Reports - 2003

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Log No Notifier Description Report Date Access No
2003-001-00 Ingersoll-Rand Unstaked Capscrews Renders Residual Heat Removal Pump Inoperable 12/20/2002 ml023650495
2003-001-01 Vogtle Inadequately Staked Capscrews Render RHR Pumps Inoperable - UPDATE 12/05/2003 ml033430282
2003-002-00 Whiting Corp One or possibly two internal support bolts in #25 Hoist Unit (Gear Case) may be significantly over-stressed 01/29/2003 ml030430027
2003-002-01 Whiting Corp Follow-up notice related to the previously reported Part 21 from Whiting Corp. dated 1/29/2003 02/12/2003 ml030520271
2003-003-00 Rockbestos-Suprenant Corp. Firewall III cables may include an alternate resin which was not part of the baseline qualification testing 01/14/2003 ml030240121
2003-003-01 Rockbestos-Suprenant Corp. Follow-up-Firewall III cables may include an alternate resin which was not part of the baseline qualification testing 02/13/2003 ml030570149
2003-004-00 Scientech Square Root Function (CMM900) modules have been found to be defective 01/14/2003 Event Notification 39516
2003-004-01 Scientech Follow-up - Square Root Function (CMM900) modules have been found to be defective 02/15/2003 ml030520269
2003-004-02 Scientek Update - Square Root Function (CMM900) modules have been found to be defective 02/05/2009 ML090400748
2003-005-00 Nine Mile Point LER - Main steam isolation valve (MSIV) disc separated from its stem allowing the disc/piston assembly to drop into the valve seat 01/07/2003 ml030230404
2003-006-00 Boeing Errors associated with the computer codes "ANSYS" and "GTSTRUDL" 01/20/2003 ml030280443
2003-006-01 Boeing Co. Transmittal of Error Notices Received from Former Software Suppliers (Followup) 12/18/2003 ml033650352
2003-007-00 Carboline Company Deficiencies in coating film affecting its a application and aesthetic properties 02/17/2003 ml030550248
2003-008-00 Holtec International Potential defect in Aalborg model GFM671S mass flow rate meters 03/06/2003 ml030690012
2003-009-00 Electrak Corp Errors associated with fire hazards module within the TRAK2000 Cable Management and Appendix R Analysis System software 03/07/2003 ml030940364
2003-010-00 Westinghouse Electric Co Failed circuit breakers manufactured by ABB and retrofitted by Westinghouse use for Class 1E applications 03/14/2003 ml030790432
2003-010-01 ABB, Inc. Clarification Regarding the Failure of Circuit Breakers Shipped to Calvert Cliffs Plant 12/26/2003 ml033650312
2003-011-00 Engine Systems Inc. Stability and amplifier gain potentiometers swap on EGM control 04/21/2003 ml031200116
2003-012-00 General Electric GE Nuclear reports a new phenomenon that causes fuel channel bowing 03/03/2003 ml031420086
2003-012-01 General Electric Interim surveillance program for fuel channel bowing 04/28/2003 ml031420346
2003-012-02 General Electric Interim surveillance program for fuel channel bowing - Plant exclusion 04/30/2003 ml031420339
2003-012-03 General Electric GE Nuclear reports a new phenomenon that causes fuel channel bowing - Update 06/06/2003 ml031700267
2003-012-04 General Electric Report involving impact of Fuels Channel Bowing - Follow-up 07/18/2003 Event Notification 40005
2003-012-05 General Electric Final Report involving impact of Fuels Channel Bowing 11/18/2003 ml033280519
2003-013-00 ABB Inc. Concerns relating to the Class 1E Type TD-5 Relay 02/24/2003 ml031830141
2003-013-01 ABB Inc. Concerns relating to the Class 1E Type TD-5 Relay - Evaluation/Followup 05/16/2003 ml031470289
2003-014-00 ABB Inc. Concerns relating to the Class 1E Type KLF/KLF-1 Relay 02/24/2003 ml031830141
2003-014-01 ABB Inc. Concerns relating to the Class 1E Type KLF/KLF-1 Relay - Evaluation/Followup 05/16/2003 ml031470313
2003-015-00 ABB Inc. Concerns relating to the Class 1E Type COV-8/COV-9 Relay 02/24/2003 ml031830141
2003-015-01 ABB Inc. Concerns relating to the Class 1E Type COV-8/COV-9 Relay - Evaluation/Followup 05/16/2003 ml031470326
2003-017-00 Engine Systems Inc. Condition reported with an EMD electric start motor at Oyster Creek Generating Station 06/11/2003 ml031690386
2003-018-00 VC Summer Failure of a Safety-Related K-Line circuit breaker 06/11/2003 ml031690399
2003-018-01 VC Summer Failure of a Safety-Related K-Line circuit breaker 02/23/2004 ml040570633
2003-019-00 Thermo Electron Corp Potential defect in Thermo Westronics Model 2100C Series Recorders 07/21/2003 ml032170035
2003-020-00 Westinghouse Electric Co Potential defect in Cuttler Hammer circuit breakers 09/04/2003 ml032510902
2003-021-00 Ederer, LLC Potential Safety hazard involving crane emergency drum brake 09/10/2003 ml032580450
2003-022-00 Florida Power & Light Issue at Seabrook regarding Spent Fuel Test Coupons 09/15/2003 ml032650709
2003-022-01 Florida Power & Light Issue at Seabrook regarding Spent Fuel Test Coupons - Followup 10/06/2003 ml032880525
2003-023-00 Framatome Report regarding failure of the Eaton Cutler - Hammer Freedom Series Heater Packs 09/30/2003 ml032750756
2003-024-00 Framatome Report regarding Eaton Cutler-Hammer Type W Vintage Unit plug in stabs 10/09/2003 ml032870422
2003-025-00 General Electric Stability Option III Period Based Detection Algorithm Allowable Settings 10/04/2003 ml032870429
2003-026-00 Callaway GE Magne-Blast Breaker Tube and Piston Assemblies 10/29/2003 Event Notification 40283
2003-027-00 Callaway GE Low Voltage Circuit Breakers 11/20/2003 Event Notification 40344
2003-028-00 VC Summer Defective Master Relay in solid state protective system 12/01/2003

Event Notification 40364

ml033520299

2003-029-00 Automatic Valve Failure of Solenoid Operated Valve to Close at Elevated Air Pressure 12/16/2003 Event Notification 40393
2003-030-00 Cardinal Health Radiation Management Services Potential Failure of Model 877-1 High Range Containment Monitor Detectors 11/18/2003 ml033240134
2003-031-00 Framatome ANP Fuel Assembly Bow Analysis 12/09/2003 ml033460173
2003-032-00 Operation Technology, Inc. Deviation Assessment ETAP Library Data 12/09/2003
10/31/2003
08/14/2003
06/23/2003
04/08/2003
03/07/2003
ml033490454
ml033080019
ml032310169
ml031750083
ml031040224
ml030660635
2003-033-00 Cardinal Health Radiation Management Services Potential Failure of Model 977-201 and 977-210 Wide Range Ion Chamber Area Monitors 12/23/2003 ml033630565
2003-033-01 Cardinal Health Radiation Management Services Potential Failure of Model 977-201 and 977-210 Wide Range Ion Chamber Area Monitors - Updated 01/28/2004 ml040300254